Pennsylvania health inspection recordFood service · 15686
Apollo - Ridge Elem School
1831 State Route 56, Spring Church, PA · (724) 478-6000
Did they pass? Yes, with conditions. Apollo - Ridge Elem School's most recent Pennsylvania health inspection, on September 22, 2026, was marked "In compliance".
- Inspections, last 12 months
- 2
- Passed
- 2
- Failed
- 0
- Visits with pests noted
- 0
- Facility type
- Food service
- Record ID
- 29488
- Last inspected
- September 22, 2026
The latest inspection, x-rayed
What the inspector found on September 22, 2026
Every inspection, newest first
-
September 22, 2026Conditional
- Approved system & cleanable fixtures Observed a shut-off style chemical box connected downstream from atmospheric vacuum breaker (avb) of mop faucet in cafeteria kitchen. Shut off valves may not remain attached downstream from avbs. Ensure connection is removed from faucet after active use. Chemical box is equipped with an asse 1055b backflow device and may be attached to a dedicated water line not equipped with an avb. Provided guidance document via email. Repeat violation (10/6/2025, 3/4/2026, & 9/22/26). What this means
- Repairing-premises, structures, attachments & fixtures-methods Observed opening in walls/missing escutcheon plates around plumbing under sink across from walk-ins. Fill/repair so no opening is present. Repeat violation (3/4/26 & 9/22/26). What this means
- Hot water and chemicals-methods Observed high temp dish machine to be at a maximum surface plate temperature of 153-158*F via min/max thermometer after multiple loads while dishes were being actively run through machine. Observed machine temp log kept by PIC to have some days where highest temp inside machine was 158*F and 159*F and no corrective action indicated on chart. Discussed with PIC that plate level temperature must reach at least 160*F for proper sanitation. Discussed ensuring hot water is available for the demand of machine use and ensure plate level temperature is at least 160*F throughout dish washing. Discussed need for facility to switch to three compartment sink sanitizing if machine is not consistently reaching 160*F. PIC stated that machine had been running for awhile before inspector arrival. PIC will monitor temperature and switch to three comp sanitation if plate level in machine is not reaching 160*F. Corrected. What this means
- System maintained in good repair Observed leak from handles of faucet when water is turned on at hand sink near office. Also observed bell cap of atmospheric vacuum breaker of mop sink faucet to be missing. Repair/replace. Repeat violation (3/4/26 & 9/22/26). What this means
-
March 4, 2026Conditional
- Repairing-premises, structures, attachments & fixtures-methods Observed opening in walls/missing escutcheon plates around plumbing under sink across from walk-ins. Fill/repair so no opening is present. What this means
- Backflow prevention device, when required Observed a y-valve style shut off valve attached downstream from atmospheric vacuum breaker (avb) of mop sink without approved testable backflow prevention device. Attached to y-valve was chemical dispenser box equipped with an asse 1055 backflow device and an open-ended hose. Avbs are not designed for constant pressure that shut off valves create. Discussed with PIC that shut off valves must be removed from mop faucet or install a testable backflow prevention device. Chemical box may be connected to a dedicated water line upstream from avb. Repeat violation (10/6/2025 & 3/4/2026). What this means
- System maintained in good repair Observed leak from handles of faucet at hand sink near office. Also observed bell cap of atmospheric vacuum breaker to be broken/not fully attached to avb. Repair. What this means
From the Pennsylvania Department of Agriculture and local health departments, published as Pennsylvania Department of Agriculture, Food Safety inspection results. Text is the inspector's, shortened only for length. Pennsylvania marks each inspection In compliance or Out of compliance. Here, Out of compliance counts as failed, In compliance with items cited counts as passed with conditions, and In compliance with nothing cited counts as passed.
Questions
Did Apollo - Ridge Elem School pass its health inspection?
Yes, with conditions. Apollo - Ridge Elem School's most recent Pennsylvania health inspection, on September 22, 2026, was marked "In compliance".
How many times was Apollo - Ridge Elem School inspected in the last year?
2 times in the last 12 months, with 0 failed results.
Who inspects Apollo - Ridge Elem School?
The Pennsylvania Department of Agriculture and local health departments. Pennsylvania marks each inspection In compliance or Out of compliance. Here, Out of compliance counts as failed, In compliance with items cited counts as passed with conditions, and In compliance with nothing cited counts as passed.