DidTheyPass
Boston health inspection record
Food inspection recordBoston Inspectional Services Department

Eating & Drinking · 02135

Peka

300 Washington St, Boston, MA

FailedNovember 3, 2026

Did they pass? No. Peka failed its most recent Boston health inspection on November 3, 2026.

Inspections, last 12 months
5
Passed
0
Failed
5
Visits with pests noted
0
Facility type
Eating & Drinking
Record ID
434267
Last inspected
November 3, 2026
Data source
Analyze Boston, Food Establishment Inspections

The latest inspection, x-rayed

What the inspector found on November 3, 2026

Every inspection, newest first

  1. November 3, 2026Failed

    Failed, extra time given to fix · Inspection

    • SeriousBackflow prevention (p) At the two bay prep sink observed a direct connection to the waste water system; have a licensed plumber pull permits at 1010 mass ave and install an indirect connection to the wastewater system at the prep sinks. What this means
  2. October 6, 2026Failed

    Failed, extra time given to fix · Inspection

    • System maintained in good repair (c) At the high temperature warewashing machine the psi gauge did not move during any part of the cycles observed; repair or replace the gauge.
    • SeriousBackflow prevention (p) At the two bay prep sink observed a direct connection to the waste water system; have a licensed plumber pull permits at 1010 mass ave and install an indirect connection to the wastewater system at the prep sinks. What this means
  3. September 29, 2026Failed

    Sent to a hearing · Inspection

    • System maintained in good repair (c) At the high temperature warewashing machine the rinse gauge and the psi gauge wash and rinse gauges did not move during any part of the cycles observed; repair or replace the gauges. An irreversible thermometer was used at the machine and registered at least 165F captured. What this means
    • Repairing-premises structures attachments and fixtures-methods (c) The floor in front of the walk-in freezer in the basement are heavily damaged; repair or replace the damaged floor What this means
    • SeriousBackflow prevention (p) At the two bay prep sink observed a direct connection to the waste water system; have a licensed plumber pull permits at 1010 mass ave and install an indirect connection to the wastewater system at the prep sinks. What this means
  4. September 22, 2026Failed

    Failed, extra time given to fix · Inspection

    • System maintained in good repair (c) At the high temperature warewashing machine the rinse gauge and the psi gauge wash and rinse gauges did not move during any part of the cycles observed; repair or replace the gauges. An irreversible thermometer was used at the machine and registered at least 165F captured. What this means
    • SeriousBackflow prevention (p) At the two bay prep sink observed a direct connection to the waste water system; have a licensed plumber pull permits at 1010 mass ave and install an indirect connection to the wastewater system at the prep sinks. What this means
    • Repairing-premises structures attachments and fixtures-methods (c) The floor in front of the walk-in freezer in the basement are heavily damaged; repair or replace the damaged floor What this means
    • Good repair and proper adjustment-equipment (c) Observed multiple damaged or missing gaskets for cold holding units in the kitchen; repair or replace the damaged or missing gaskets. What this means
  5. September 15, 2026Failed

    Failed · Inspection

    • Handwashing signage (c) The first floor woman's room and the employee restroom in the basement lack handwashing signage; provide. What this means
    • Repairing-premises structures attachments and fixtures-methods (c) The floor at the landing leading towards the basement and the floor in front of the walk-in freezer in the basement are heavily damaged the grout is low in the kitchen area in front of the prep sink and in front of the high temperature warewashing machine; repair or replace the damaged items. What this means
    • Toilet room receptacle covered (c) Provide a covered waste receptacle in the employee restroom for sanitary products.
    • Maintaining refuse areas and enclosures (c) There is excessive refuse and items scattered around the exterior refuse area; remove the excessive items to prevent pest harborage.
    • SeriousBackflow prevention (p) At the two bay prep sink observed a direct connection to the waste water system; have a licensed plumber pull permits at 1010 mass ave and install an indirect connection to the wastewater system at the prep sinks. What this means
    • System maintained in good repair (c) At the high temperature warewashing machine the rinse gauge and the psi gauge did not move during any part of the cycles observed; repair or replace the gauges. An irreversible thermometer was used at the machine and registered at least 165F captured. What this means
    • Good repair and proper adjustment-equipment (c) Observed multiple damaged or missing gaskets for cold holding units in the kitchen; repair or replace the damaged or missing gaskets. What this means
    • SeriousManual and mechanical warewashing equipment chemical sanitization-temperature ph concentration and hardness (p) At the bar chemical warewashing machine tested 0ppm chlorine after multiple run attempts; the person in charge placed a call for service during the inspection and has instructed staff to use the warewashing machine in the kitchen to wash and sanitize until the warewashing machine at the bar is repaired. Chemical sanitizer should be at minimum PPM required by the food code. What this means
    • SeriousFood temperature measuring devices (pf) The presented food thermometer was only capable of measuring ambient and hot foods; provide a thin stemmed food thermometer capable of measuring cold and hot foods. What this means
    • SeriousClean-up of vomiting and diarrheal events (pf) No written instructions on how to handle a vomit and diarrhea event could be presented during the inspection; provide. What this means

From the Boston Inspectional Services Department, published as Analyze Boston, Food Establishment Inspections. Text is the inspector's, shortened only for length. Boston marks each inspection Pass or Fail. A suspended permit, a hearing or a voluntary closure also counts as failed here. Violations marked with two or three stars are the serious ones.

Questions

Did Peka pass its health inspection?

No. Peka failed its most recent Boston health inspection on November 3, 2026.

How many times was Peka inspected in the last year?

5 times in the last 12 months, with 5 failed results.

Who inspects Peka?

The Boston Inspectional Services Department. Boston marks each inspection Pass or Fail. A suspended permit, a hearing or a voluntary closure also counts as failed here. Violations marked with two or three stars are the serious ones.